73188RESERVE NOTICE31/01/2020 03:01:50 PM

Actual Lack Of Reserve Level 2 (LOR2) in the NSW region - 31/01/2020

AEMO ELECTRICITY MARKET NOTICE

An Actual LOR2 condition has been declared for the NSW region from 1500 hrs.
The capacity reserve required is 775 MW
The minimum reserve available is 500 MW

AEMO is seeking an immediate market response.

An insufficient market response may require AEMO to implement a AEMO intervention event.

Manager NEM Real Time Operations
73187MARKET INTERVENTION31/01/2020 02:26:56 PM

RERT DISPATCHED

AEMO ELECTRICITY MARKET NOTICE.

AEMO Intervention Event, Reliability and Emergency Reserve Trader (RERT) - VIC1 Region- 31/01/2020

Refer AEMO Electricity Market Notice no. 73183
AEMO has dispatched/activated reserve contract(s) to maintain the power system in a Secure and Reliable operating state.
The reserve contract(s) was dispatched/activated at 15:30 hrs 31/01/2020 and is forecast to apply until 21:30 hrs 31/01/2020
AEMO has implemented an AEMO intervention event for the duration the reserve contract(s) is dispatched/activated/
To facilitate the RERT process, constraints commencing with the following identifiers may be evident at various times in dispatch,

#RT_VIC1


Manager NEM Real Time Operations
73186SETTLEMENTS RESIDUE31/01/2020 02:20:45 PM

[EventId:202001311420_NRM_VIC1_NSW1_stopped] NEGRES CONSTRAINT NRM_VIC1_NSW1 ceased operating from 31 January 2020 14:20

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1420 hrs on 31 January 2020

CANCELLATION - ACTUAL NEGATIVE SETTLEMENT RESIDUES - VIC to NSW - 31 January 2020.

Refer to market notice: 73179

AEMO has ceased taking action to minimize the further accumulation of negative settlement residues on the VIC to NSW directional interconnector.

The negative residue constraint NRM_VIC1_NSW1 ceased operating at 1420 hrs on 31 January 2020.

This is an AEMO autogenerated Market Notice.
73185NON-CONFORMANCE31/01/2020 02:20:11 PM

NON-CONFORMANCE Region SA1 Friday, 31 January 2020

AEMO ELECTRICITY MARKET NOTICE

NON-CONFORMANCE SA1 Region Friday, 31 January 2020

AEMO declared a schedule generating unit non-conforming

Unit: DRYCGT3
Duration: 31/01/2020 14:15 to 31/01/2020 14:20
Amount: -27 MW
Constraint: NC-S_DRYCGT3

Auto-generated on behalf of Manager NEM Real Time Operations
73184MARKET INTERVENTION31/01/2020 02:24:35 PM

Direction - SA region 31/01/2020

AEMO ELECTRICITY MARKET NOTICE.

Direction - SA region 31/01/2020

In accordance with section 116 of the National Electricity Law, AEMO has issued a direction to a participant in the SA region. For the purposes of the National Electricity Rules this is a direction under clause 4.8.9(a).

The direction was necessary to maintain the power system in a secure operating state.

AEMO may issue or revoke additional directions in order to meet the current requirement, unless sufficient market response is provided. A further market notice will be issued when all directions related to this requirement have been cancelled.

The issue of the direction commences an AEMO intervention event. AEMO declares all dispatch intervals during the event to be intervention dispatch intervals, commencing from the interval ending 1400 hrs on 31/01/2020

Intervention pricing does not apply to this AEMO intervention event.


Manager NEM Real Time Operations
73183RESERVE NOTICE31/01/2020 02:16:13 PM

Actual Lack Of Reserve Level 2 (LOR2) in the VIC region - 31/01/2020

AEMO ELECTRICITY MARKET NOTICE

An Actual LOR2 condition has been declared for the VIC region from 1400 hrs.
The capacity reserve required is 560 MW
The minimum reserve available is 200 MW

AEMO is seeking an immediate market response.

An insufficient market response may require AEMO to implement a AEMO intervention event.

Manager NEM Real Time Operations
73182SETTLEMENTS RESIDUE31/01/2020 02:05:21 PM

[EventId:202001311405_NRM_NSW1_VIC1_started] NEGRES CONSTRAINT NRM_NSW1_VIC1 started operating from 31 January 2020 14:05

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1405 hrs on 31 January 2020

ACTUAL NEGATIVE SETTLEMENT RESIDUES - NSW to VIC - 31 January 2020.

Electricity Market outcomes have resulted in the accumulation of negative settlement residues that have exceeded the allowable negative residue threshold for the NSW to VIC directional interconnector.

The negative residue constraint set NRM_NSW1_VIC1 commenced operating from 1405 hrs on 31 January 2020.

This constraint set contains an equation with the following interconnectors on the LHS:
VIC1-NSW1

The RHS of the constraint equation may be adjusted to manage residues.


This is an AEMO autogenerated Market Notice.
73181RESERVE NOTICE31/01/2020 02:04:39 PM

Correction - PDPASA - Forecast Lack Of Reserve Level 2 (LOR2) in the Vic Region on 31/01/2020

AEMO ELECTRICITY MARKET NOTICE

Correction to MN 73173 - Date corrected.

AEMO declares a Forecast LOR2 condition under clause 4.8.4(b) of the National Electricity Rules for the Vic region for the following period:

From 1500 hrs 31/01/2020 to 1800 hrs 31/01/2020.
The forecast capacity reserve requirement is 1105 MW.
The minimum capacity reserve available is 406 MW.

AEMO is seeking a market response.
AEMO estimates the latest time at which it would need to intervene through an AEMO intervention event is 1300 hrs on 31/12/2020]

Manager NEM Real Time Operations
73179SETTLEMENTS RESIDUE31/01/2020 02:01:39 PM

[EventId:202001311400_NRM_VIC1_NSW1_started] NEGRES CONSTRAINT NRM_VIC1_NSW1 started operating from 31 January 2020 14:00

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1400 hrs on 31 January 2020

ACTUAL NEGATIVE SETTLEMENT RESIDUES - VIC to NSW - 31 January 2020.

Electricity Market outcomes have resulted in the accumulation of negative settlement residues that have exceeded the allowable negative residue threshold for the VIC to NSW directional interconnector.

The negative residue constraint set NRM_VIC1_NSW1 commenced operating from 1400 hrs on 31 January 2020.

This constraint set contains an equation with the following interconnectors on the LHS:
VIC1-NSW1

The RHS of the constraint equation may be adjusted to manage residues.


This is an AEMO autogenerated Market Notice.