Cancellation: Direction issued to: AGL SA Generation Pty Limited - TORRB3 TORRENS ISLAN
Cancellation: Direction issued to: AGL SA Generation Pty Limited - TORRB3 TORRENS ISLAN
Refer to Market Notice 120272
Direction is cancelled from: 1430 hrs 12/11/2024
Manager NEM Real Time Operations
Cancellation: Direction issued to: Synergen Power Pty Limited - MINTARO MINTARO GAS
Cancellation: Direction issued to: Synergen Power Pty Limited - MINTARO MINTARO GAS
Refer to Market Notice 120272
Direction is cancelled from: 1430 hrs 12/11/2024
Manager NEM Real Time Operations
[EventId:202411111740_confirmed] Prices for interval 11-Nov-2024 17:40 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1800 hrs on 11 November 2024
PRICES ARE NOW CONFIRMED for trading interval 11-Nov-2024 17:40.
In accordance with Market Notice 120278 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202411111800_confirmed] Prices for interval 11-Nov-2024 18:00 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1800 hrs on 11 November 2024
PRICES ARE NOW CONFIRMED for trading interval 11-Nov-2024 18:00.
In accordance with Market Notice 120284 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202411111755_confirmed] Prices for interval 11-Nov-2024 17:55 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1800 hrs on 11 November 2024
PRICES ARE NOW CONFIRMED for trading interval 11-Nov-2024 17:55.
In accordance with Market Notice 120281 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202411111750_confirmed] Prices for interval 11-Nov-2024 17:50 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1800 hrs on 11 November 2024
PRICES ARE NOW CONFIRMED for trading interval 11-Nov-2024 17:50.
In accordance with Market Notice 120280 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202411111745_confirmed] Prices for interval 11-Nov-2024 17:45 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1800 hrs on 11 November 2024
PRICES ARE NOW CONFIRMED for trading interval 11-Nov-2024 17:45.
In accordance with Market Notice 120279 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202411111735_confirmed] Prices for interval 11-Nov-2024 17:35 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1800 hrs on 11 November 2024
PRICES ARE NOW CONFIRMED for trading interval 11-Nov-2024 17:35.
In accordance with Market Notice 120277 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
Direction - SA region to Synergen Power Pty Limited - MINTARO MINTARO GAS
Direction - SA region to Synergen Power Pty Limited - MINTARO MINTARO GAS
Refer to Market Notice 120272
In accordance with section 116 of the National Electricity Law, AEMO is issuing a direction to Synergen Power Pty Limited. For the purposes of the National Electricity Rules this is a direction under clause 4.8.9(a1)(1).
Direction issued to: Synergen Power Pty Limited - MINTARO MINTARO GAS at 1600 hrs 11/11/2024
Type of resource: generating unit
Required actions: Remain synchronised and follow dispatch targets at 0830 hrs 12/11/2024
Services provided: Voltage Control
Circumstances necessitating the Direction: Voltage
Circumstances necessitating the Direction additional detail: The synchronous generating units currently expected to be synchronised in SA will be inadequate to maintain sufficient Voltage Control in SA. Intervention is required to maintain the power system in a secure operating state
Expected duration: 1430 hrs 12/11/2024 / further notice.
Synergen Power Pty Limited does not incur any civil monetary liability for a relevant action taken in accordance with this direction unless the action is taken in bad faith.
Manager NEM Real Time Operations