83071NON-CONFORMANCE01/03/2021 08:20:16 AM

NON-CONFORMANCE Region NSW1 Monday, 1 March 2021

AEMO ELECTRICITY MARKET NOTICE

NON-CONFORMANCE NSW1 Region Monday, 1 March 2021

AEMO declared a schedule generating unit non-conforming

Unit: MANSLR1
Duration: 01/03/2021 08:00 to 01/03/2021 08:20
Amount: 22 MW
Constraint: NC-N_MANSLR1

Auto-generated on behalf of Manager NEM Real Time Operations
83069RECLASSIFY CONTINGENCY28/02/2021 08:09:36 PM

Cancellation of a Non-Credible Contingency Event: Bulli Creek - Dumaresq 8L 330KV line and Bulli Creek - Dumaresq 8M 330KV line in QLD1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: QLD1

Lines: Bulli Creek - Dumaresq 8L 330KV and Bulli Creek - Dumaresq 8M 330KV

Cancellation time: 28/02/2021 20:09

Constraint set(s) revoked:
I-QNI_ONE_PHASE_N-2 Constraint set contains the following interconnector(s) on the left hand side:
NSW1-QLD1


Refer AEMO Electricity Market Notice 83066

Auto-generated on behalf of Manager NEM Real Time Operations
83066RECLASSIFY CONTINGENCY28/02/2021 05:04:00 PM

Reclassification of a Non-Credible Contingency Event: Bulli Creek - Dumaresq 8L 330KV line and Bulli Creek - Dumaresq 8M 330KV line in QLD1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.

Region: QLD1

Lines: Bulli Creek - Dumaresq 8L 330KV and Bulli Creek - Dumaresq 8M 330KV

Duration: 28/02/2021 17:03 until further notice

Constraint set(s) invoked:
I-QNI_ONE_PHASE_N-2 Constraint set contains the following interconnector(s) on the left hand side:
NSW1-QLD1


Auto-generated on behalf of Manager NEM Real Time Operations
83065RECLASSIFY CONTINGENCY28/02/2021 04:44:35 PM

Cancellation of a Non-Credible Contingency Event: Bulli Creek - Dumaresq 8L 330KV line and Bulli Creek - Dumaresq 8M 330KV line in QLD1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: QLD1

Lines: Bulli Creek - Dumaresq 8L 330KV and Bulli Creek - Dumaresq 8M 330KV

Cancellation time: 28/02/2021 16:44

Constraint set(s) revoked:
I-QNI_ONE_PHASE_N-2 Constraint set contains the following interconnector(s) on the left hand side:
NSW1-QLD1


Refer AEMO Electricity Market Notice 83064

Auto-generated on behalf of Manager NEM Real Time Operations
83064RECLASSIFY CONTINGENCY28/02/2021 03:39:40 PM

Reclassification of a Non-Credible Contingency Event: Bulli Creek - Dumaresq 8L 330KV line and Bulli Creek - Dumaresq 8M 330KV line in QLD1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.

Region: QLD1

Lines: Bulli Creek - Dumaresq 8L 330KV and Bulli Creek - Dumaresq 8M 330KV

Duration: 28/02/2021 15:39 until further notice

Constraint set(s) invoked:
I-QNI_ONE_PHASE_N-2 Constraint set contains the following interconnector(s) on the left hand side:
NSW1-QLD1


Auto-generated on behalf of Manager NEM Real Time Operations
83057RECLASSIFY CONTINGENCY28/02/2021 11:52:45 AM

Reclassification of a Non-Credible Contingency Event as a Credible Contingency: Baralaba - Moura 7112 132 kV Transmission line opening at the Baralaba end only - 28/02/2021

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event as a Credible Contingency: Baralaba - Moura 7112 132 kV Transmission line opening at the Baralaba end only - 28/02/2021

AEMO considers the opening of the Baralaba - Moura 7112 132 kV Transmission line at the Baralaba end only now to be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.

Refer to AEMO Electricity Market Notice 83056

Region: QLD1

Lines: Baralaba - Moura 7112 132 kV Transmission line

Duration: 28/02/2021 1145 hrs until further notice

Constraint set(s) invoked: NONE


Manager NEM Real Time Operations
83056POWER SYSTEM EVENTS28/02/2021 01:23:49 AM

Non-credible contingency event - QLD region - 28/02/2021

AEMO ELECTRICITY MARKET NOTICE

Non-credible contingency event - QLD region - 28/02/2021

At 0049 hrs 28/02/2021 the Baralaba - Moura 7112 132 kV Transmission line opened at the Baralaba end only.

The cause of this non credible contingency event is not known at this stage.

Manager NEM Real Time Operations
83044MARKET INTERVENTION25/02/2021 11:30:59 PM

Direction - SA region 25/02/2021

AEMO ELECTRICITY MARKET NOTICE.

Direction - SA region 25/02/2021

In accordance with section 116 of the National Electricity Law, AEMO has issued a direction to a participant in the SA region. For the purposes of the National Electricity Rules this is a direction under clause 4.8.9(a).

The direction was necessary to maintain the power system in a secure operating state.

AEMO may issue or revoke additional directions in order to meet the current requirement, unless sufficient market response is provided. A further market notice will be issued when all directions related to this requirement have been cancelled.

The issue of the direction commences an AEMO intervention event. AEMO declares all dispatch intervals during the event to be intervention dispatch intervals, commencing from the interval ending 2335 hrs on 25/02/2021.

Intervention pricing does not apply to this AEMO intervention event.

Manager NEM Real Time Operations
83042RECLASSIFY CONTINGENCY25/02/2021 08:44:35 PM

Cancellation of a Non-Credible Contingency Event: Lismore - Dunoon 9U6 132kV line and Lismore - Dunoon 9U7 132kV line in NSW1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: NSW1

Lines: Lismore - Dunoon 9U6 132kV and Lismore - Dunoon 9U7 132kV

Cancellation time: 25/02/2021 20:44

Constraint set(s) revoked:
NONE

Refer AEMO Electricity Market Notice 83041

Auto-generated on behalf of Manager NEM Real Time Operations