Market Notices

123277PRICES SUBJECT TO REVIEW15/01/2025 02:27:05 PM

[EventId:202501151425_review] Prices for interval 15-Jan-2025 14:25 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1420 hrs on 15 January 2025

PRICES ARE SUBJECT TO REVIEW for trading interval 15-Jan-2025 14:25.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
     
123276INTER-REGIONAL TRANSFER15/01/2025 02:21:49 PM

Inter-regional transfer limit variation - Murray - Lower Tumut 330 kV 66 line - NSW region - 15/01/2025

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - Murray - Lower Tumut 330 kV 66 line - NSW region - 15/01/2025

At 1400 hrs 15/01/2025 there was an unplanned outage of Murray - Lower Tumut 330 kV 66 line.

The following constraint set(s) invoked at 1415 hrs 15/01/2025
I-LTMS

This constraint set(s) contains equations with the following interconnectors on the LHS.
VIC1-NSW1,V-S-MNSP1,NSW1-QLD1,T-V-MNSP1

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
     
123275PRICES SUBJECT TO REVIEW15/01/2025 02:15:26 PM

[EventId:202501151420_review] Prices for interval 15-Jan-2025 14:20 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1415 hrs on 15 January 2025

PRICES ARE SUBJECT TO REVIEW for trading interval 15-Jan-2025 14:20.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
     
123274PRICES SUBJECT TO REVIEW15/01/2025 02:10:16 PM

[EventId:202501151415_review] Prices for interval 15-Jan-2025 14:15 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1410 hrs on 15 January 2025

PRICES ARE SUBJECT TO REVIEW for trading interval 15-Jan-2025 14:15.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
     
123273INTER-REGIONAL TRANSFER15/01/2025 02:28:14 PM

Inter-regional transfer limit variation - Lower Tumut - Yass 330 kV 03 Line - NSW region - 15/01/2025

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - Lower Tumut - Yass 330 kV 03 Line - NSW region - 15/01/2025

At 1358 hrs 15/01/2025 there was an unplanned outage of Lower Tumut - Yass 330 kV 03 Line.

The following constraint set(s) invoked at 1400 hrs 15/01/2025
N-X_LTYS_MNYS

This constraint set(s) contains equations with the following interconnectors on the LHS.
VIC1-NSW1,N-Q-MNSP1,NSW1-QLD1,V-S-MNSP1

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
     
123271PRICES SUBJECT TO REVIEW15/01/2025 02:05:31 PM

[EventId:202501151410_review] Prices for interval 15-Jan-2025 14:10 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1405 hrs on 15 January 2025

PRICES ARE SUBJECT TO REVIEW for trading interval 15-Jan-2025 14:10.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
     
123269INTER-REGIONAL TRANSFER15/01/2025 02:25:37 PM

Inter-regional transfer limit variation - Muswellbrook 330/132 kV Transformer 1 - NSW region - 15/01/2025

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - Muswellbrook 330/132 kV Transformer 1 - NSW region - 15/01/2025

At 1337 hrs 15/01/2025 there was an unplanned outage of Muswellbrook 330/132 kV Transformer 1.

The following constraint set(s) invoked at 1355 hrs 15/01/2025
N-MUTW_88

This constraint set(s) contains equations with the following interconnectors on the LHS.
N-Q-MNSP1,NSW1-QLD1,T-V-MNSP1

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
     
123268PRICES SUBJECT TO REVIEW15/01/2025 02:00:30 PM

[EventId:202501151405_review] Prices for interval 15-Jan-2025 14:05 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1400 hrs on 15 January 2025

PRICES ARE SUBJECT TO REVIEW for trading interval 15-Jan-2025 14:05.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
     
123266PRICES SUBJECT TO REVIEW15/01/2025 01:55:30 PM

[EventId:202501151400_review] Prices for interval 15-Jan-2025 14:00 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1355 hrs on 15 January 2025

PRICES ARE SUBJECT TO REVIEW for trading interval 15-Jan-2025 14:00.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
     
X
Cookies help us improve your website experience.
By using our website, you agree to our use of cookies.
Confirm