Filter by category
Filter by Date
NEM Local Temperature Alerts for SA, VIC from 10 Jan 2025 to 14 Jan 2025
AEMO's weather service provider has issued forecast temperatures equal to or greater than the NEM Local Temperature Alert Levels for listed weather stations below.
SA
Port Augusta Ap (39+ Deg C): 11th Jan, 14th Jan
VIC
Mildura Ap (39+ Deg C): 12th Jan, 13th Jan, 14th Jan
The NEM Local Temperature Alert Levels are:
Launceston Ti Tree Bend: 33 Deg C, Dalby Airport: 37 Deg C, for all other selected weather stations: 39 Deg C.
AEMO requests Market Participants to:
1. review the weather forecast in the local area where their generating units / MNSP converter stations are located and,
2. if required, update the available capacity in their dispatch offers or availability submissions consistent with the forecast temperatures.
Further information is available at:
https://aemo.com.au/energy-systems/electricity/national-electricity-market-nem/nem-forecasting-and-planning/forecasting-and-reliability/projected-assessment-of-system-adequacy/nem-local-temperature-alerts
AEMO Operations Planning
Cancellation of a Non-Credible Contingency Event: Armidale - Dumaresq 8C 330kV line and Armidale - Sapphire WF 8E 330kV line in NSW1 due to Lightning.
Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.
Region: NSW1
Lines: Armidale - Dumaresq 8C 330kV and Armidale - Sapphire WF 8E 330kV
Cancellation time: 09/01/2025 13:54
Constraint set(s) revoked:
N-ARDM_ARSR_1PH_N-2 Constraint set contains the following interconnector(s) on the left hand side:
N-Q-MNSP1
NSW1-QLD1
Refer AEMO Electricity Market Notice 122986
Auto-generated on behalf of Manager NEM Real Time Operations
Reclassification of a Non-Credible Contingency Event: Armidale - Dumaresq 8C 330kV line and Armidale - Sapphire WF 8E 330kV line in NSW1 due to Lightning.
Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.
Region: NSW1
Lines: Armidale - Dumaresq 8C 330kV and Armidale - Sapphire WF 8E 330kV
Duration: 09/01/2025 12:51 until further notice
Constraint set(s) invoked:
N-ARDM_ARSR_1PH_N-2 Constraint set contains the following interconnector(s) on the left hand side:
N-Q-MNSP1
NSW1-QLD1
Auto-generated on behalf of Manager NEM Real Time Operations
[EventId:202501081400_review] Prices for interval 08-Jan-2025 14:00 are subject to review
Issued by Australian Energy Market Operator Ltd at 1355 hrs on 8 January 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 08-Jan-2025 14:00.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202501081355_review] Prices for interval 08-Jan-2025 13:55 are subject to review
Issued by Australian Energy Market Operator Ltd at 1350 hrs on 8 January 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 08-Jan-2025 13:55.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202501081350_review] Prices for interval 08-Jan-2025 13:50 are subject to review
Issued by Australian Energy Market Operator Ltd at 1345 hrs on 8 January 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 08-Jan-2025 13:50.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202501081345_review] Prices for interval 08-Jan-2025 13:45 are subject to review
Issued by Australian Energy Market Operator Ltd at 1340 hrs on 8 January 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 08-Jan-2025 13:45.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202501081340_review] Prices for interval 08-Jan-2025 13:40 are subject to review
Issued by Australian Energy Market Operator Ltd at 1335 hrs on 8 January 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 08-Jan-2025 13:40.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202501081335_review] Prices for interval 08-Jan-2025 13:35 are subject to review
Issued by Australian Energy Market Operator Ltd at 1330 hrs on 8 January 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 08-Jan-2025 13:35.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.