STPASA - Update of the Forecast Lack Of Reserve Level 2 (LOR2) in the NSW Region 19/07/2021
The Forecast LOR2 conditions in the NSW region advised in AEMO Electricity Market Notice No. 88279 have been updated at 1400 hrs 16/07/2021 to the following:
1. From 0800 hrs 19/07/2021 to 0830 hrs 19/07/2021.
The forecast capacity reserve requirement is 1385 MW.
The minimum capacity reserve available is 1314 MW.
2. From 1800 hrs 19/07/2021 to 1900 hrs 19/07/2021.
The forecast capacity reserve requirement is 730 MW.
The minimum capacity reserve available is 579 MW.
AEMO is seeking a market response.
AEMO has not yet estimated the latest time it would need to intervene through an AEMO intervention event.
AEMO Operations
STPASA - Update of the Forecast Lack Of Reserve Level 2 (LOR2) in the NSW Region 19/07/2021 and 21/07/2021
The Forecast LOR2 conditions in the NSW region advised in AEMO Electricity Market Notice No. 88276 have been updated at 1100 hrs 16/07/2021 to the following:
From 1800 hrs 19/07/2021 to 1900 hrs 19/07/2021.
The forecast capacity reserve requirement is 730 MW.
The minimum capacity reserve available is 560 MW.
The Forecast LOR2 condition on 21/07/2021 in the NSW region advised in AEMO Electricity Market Notice No. 88276 is cancelled.
AEMO is seeking a market response.
AEMO has not yet estimated the latest time it would need to intervene through an AEMO intervention event.
AEMO Operations
STPASA - Update of the Forecast Lack Of Reserve Level 2 (LOR2) in the QLD Region 19/07/2021- 21/07/2021
The Forecast LOR2 conditions in the QLD region advised in AEMO Electricity Market Notice No. 88277 have been updated at 1100 hrs 16/07/2021 to the following:
1. From 1730 hrs 19/07/2021 to 1900 hrs 19/07/2021.
The forecast capacity reserve requirement is 720 MW.
The minimum capacity reserve available is 590 MW.
2. From 1800 hrs 20/07/2021 to 1900 hrs 20/07/2021.
The forecast capacity reserve requirement is 720 MW.
The minimum capacity reserve available is 622 MW.
The Forecast LOR2 condition on 21/07/2021 in the QLD region advised in AEMO Electricity Market Notice No. 88277 is cancelled.
AEMO is seeking a market response.
AEMO has not yet estimated the latest time it would need to intervene through an AEMO intervention event.
AEMO Operations
STPASA - Forecast Lack Of Reserve Level 2 (LOR2) in the QLD Region 19/07/2021 - 21/07/2021
AEMO declares a Forecast LOR2 condition under clause 4.8.4(b) of the National Electricity Rules for the QLD region for the following periods:
1. From 1730 hrs 19/07/2021 to 1930 hrs 19/07/2021.
The forecast capacity reserve requirement is 720 MW.
The minimum capacity reserve available is 571 MW.
2. From 1800 hrs 20/07/2021 to 1900 hrs 20/07/2021.
The forecast capacity reserve requirement is 720 MW.
The minimum capacity reserve available is 619 MW.
3. From 1800 hrs 21/07/2021 to 1900 hrs 21/07/2021.
The forecast capacity reserve requirement is 720 MW.
The minimum capacity reserve available is 586 MW.
AEMO is seeking a market response.
AEMO has not yet estimated the latest time it would need to intervene through an AEMO intervention event.
AEMO Operations
STPASA - Update of the Forecast Lack Of Reserve Level 2 (LOR2) in the NSW Region 19/07/2021 and 21/07/2021
The Forecast LOR2 condition in the NSW region advised in AEMO Electricity Market Notice No. 88173 has been updated at 0800 hrs 16/07/2021 to the following:
1. From 1730 hrs 19/07/2021 to 1900 hrs 19/07/2021.
The forecast capacity reserve requirement is 730 MW.
The minimum capacity reserve available is 510 MW.
2. From 1800 hrs 21/07/2021 to 1900 hrs 21/07/2021.
The forecast capacity reserve requirement is 730 MW.
The minimum capacity reserve available is 586 MW.
AEMO is seeking a market response.
AEMO has not yet estimated the latest time it would need to intervene through an AEMO intervention event.
AEMO Operations
Cancellation of a Non-Credible Contingency Event: Eildon PS - Mt Beauty No.1 220 kV line and Eildon PS - Mt Beauty No.2 220 kV line in VIC1 due to Lightning.
Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.
Region: VIC1
Lines: Eildon PS - Mt Beauty No.1 220 kV and Eildon PS - Mt Beauty No.2 220 kV
Cancellation time: 16/07/2021 00:29
Constraint set(s) revoked:
NONE
Refer AEMO Electricity Market Notice 88272
Auto-generated on behalf of Manager NEM Real Time Operations
Cancellation of a Non-Credible Contingency Event: Bulli Creek - Dumaresq 8L 330KV line and Bulli Creek - Dumaresq 8M 330KV line in QLD1 due to Lightning.
Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.
Region: QLD1
Lines: Bulli Creek - Dumaresq 8L 330KV and Bulli Creek - Dumaresq 8M 330KV
Cancellation time: 15/07/2021 23:29
Constraint set(s) revoked:
I-QNI_ONE_PHASE_N-2 Constraint set contains the following interconnector(s) on the left hand side:
NSW1-QLD1
Refer AEMO Electricity Market Notice 88273
Auto-generated on behalf of Manager NEM Real Time Operations
Reclassification of a Non-Credible Contingency Event: Bulli Creek - Dumaresq 8L 330KV line and Bulli Creek - Dumaresq 8M 330KV line in QLD1 due to Lightning.
Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.
Region: QLD1
Lines: Bulli Creek - Dumaresq 8L 330KV and Bulli Creek - Dumaresq 8M 330KV
Duration: 15/07/2021 22:28 until further notice
Constraint set(s) invoked:
I-QNI_ONE_PHASE_N-2 Constraint set contains the following interconnector(s) on the left hand side:
NSW1-QLD1
Auto-generated on behalf of Manager NEM Real Time Operations
Reclassification of a Non-Credible Contingency Event: Eildon PS - Mt Beauty No.1 220 kV line and Eildon PS - Mt Beauty No.2 220 kV line in VIC1 due to Lightning.
Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.
Region: VIC1
Lines: Eildon PS - Mt Beauty No.1 220 kV and Eildon PS - Mt Beauty No.2 220 kV
Duration: 15/07/2021 22:28 until further notice
Constraint set(s) invoked:
NONE
Auto-generated on behalf of Manager NEM Real Time Operations