Market Notices

86824MARKET INTERVENTION09/06/2021 02:25:16 PM

Possible intervention to manage power system security in South Australia (SA) Region

AEMO ELECTRICITY MARKET NOTICE

Possible intervention to manage power system security in South Australia (SA) Region

The synchronous generating units expected to be synchronised in SA from 1030 hrs 10/06/2021 to 1530 hrs 10/06/2021 in Pre-dispatch published at 1400 hrs 09/06/2021 are inadequate to maintain sufficient system strength in SA and hence a secure operating state.

AEMO currently estimates that, in the absence of sufficient market response by 1800 hrs 09/06/2021, AEMO may need to intervene by issuing a direction requiring one or more SA synchronous generating unit(s) to operate or remain synchronised to maintain power system security in SA.

Manager NEM Real Time Operations
86823CONSTRAINTS09/06/2021 02:23:31 PM

Update to system strength requirements in North Queensland

AEMO ELECTRICITY MARKET NOTICE

Refer to market notice 86121 and 79837

AEMO and Powerlink are continuing to investigate system strength requirements in North Queensland.


A revision to the constraint equations will be implemented at 1000 hrs Thursday 10th June 2021.

The new combinations have now published in a limits advice document on AEMO's website: For more information refer to the new limits advice: https://www.aemo.com.au/energy-systems/electricity/national-electricity-market-nem/system-operations/congestion-information-resource/limits-advice

This advice contains all the combinations for Queensland for system normal cases.

The constraint equations in the Q-NIL set of the form below will be modified:

Q_NIL_STRGTH_XXX

For further details please contact James Lindley at james.lindley@aemo.com.au or Simon Taylor at businessdevelopment@powerlink.com.au

Ben Blake
AEMO Operations
86822PRICES SUBJECT TO REVIEW09/06/2021 02:20:12 PM

[EventId:202106091425_review] Prices for interval 09-Jun-2021 14:25 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1420 hrs on 9 June 2021

PRICES ARE SUBJECT TO REVIEW for dispatch interval 09-Jun-2021 14:25.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
86821PRICES SUBJECT TO REVIEW09/06/2021 02:15:14 PM

[EventId:202106091420_review] Prices for interval 09-Jun-2021 14:20 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1415 hrs on 9 June 2021

PRICES ARE SUBJECT TO REVIEW for dispatch interval 09-Jun-2021 14:20.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
86820PRICES SUBJECT TO REVIEW09/06/2021 02:10:14 PM

[EventId:202106091415_review] Prices for interval 09-Jun-2021 14:15 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1410 hrs on 9 June 2021

PRICES ARE SUBJECT TO REVIEW for dispatch interval 09-Jun-2021 14:15.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
86819RESERVE NOTICE09/06/2021 01:14:44 PM

STPASA - Cancellation of the Forecast Lack Of Reserve Level 2 (LOR2) in the NSW Region on 10/06/2021

AEMO ELECTRICITY MARKET NOTICE

The Forecast LOR2 condition in the NSW region advised in AEMO Electricity Market Notice No. 86817 is cancelled at 1200 hrs 09/06/2021.

No LOR2 condition is currently forecast in the STPASA period.


AEMO Operations
86818RESERVE NOTICE09/06/2021 12:51:34 PM

PDPASA - Forecast Lack Of Reserve Level 1 (LOR1) in the NSW Region on 10/06/2021

AEMO ELECTRICITY MARKET NOTICE

AEMO declares a Forecast LOR1 condition under clause 4.8.4(b) of the National Electricity Rules for the NSW region for the following period:

From 1730 hrs 10/06/2021 to 1830 hrs 10/06/2021
The forecast capacity reserve requirement is 1400 MW.
The minimum capacity reserve available is 1283 MW.

Manager NEM Real Time Operations
86817RESERVE NOTICE09/06/2021 05:26:12 AM

STPASA - Forecast Lack Of Reserve Level 2 (LOR2) in the NSW Region on 10/06/2021


AEMO ELECTRICITY MARKET NOTICE

AEMO declares a Forecast LOR2 condition under clause 4.8.4(b) of the National Electricity Rules for the NSW region for the following period[s]:

[1.] From 1730 hrs 10/06/2021 to 1830 hrs 10/06/2021
The forecast capacity reserve requirement is 1371 MW
The minimum capacity reserve available is 1196 MW.


AEMO is seeking a market response.

AEMO has not yet estimated the latest time it would need to intervene through an AEMO intervention event.

Manager NEM Real Time Operations
86816ADMINISTERED PRICE CAP09/06/2021 03:56:16 AM

[EventId:143] AP STARTED for market ancillary services in QLD at 09 June 2021 04:00

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 0355 hrs on 9 June 2021

ADMINISTERED PRICE PERIOD DECLARED in QLD region.

AEMO has determined that the rolling sum of the uncapped market ancillary Raise 6 Sec services(s) prices for the QLD region over the previous 2016 dispatch intervals has exceeded 6 times the cumulative price threshold (CPT) of $224,600.00.

In accordance with Clause 3.14 of the National Electricity Rules, AEMO has determined that an administered price period will commence at the dispatch interval starting 0400 hrs on 9 Jun 2021 and will continue through to the end of that trading day.

An administered price cap (APC) of 300 $/MWh will apply to all dispatch intervals during this administered price period. This APC will apply to all market ancillary service prices in the QLD region.

An administered floor price (AFP) of 0 $/MWh AFP will apply to all market ancillary service prices.

AEMO will continue to monitor the rolling sum of the uncapped market ancillary service prices and issue further market notices as required.


This is an AEMO autogenerated Market Notice.