80272RECLASSIFY CONTINGENCY23/11/2020 07:09:10 PM

Cancellation of a Non-Credible Contingency Event: Bayswater - Mt Piper No.5A3 500kV line and Wollar - Mt Piper No.5A5 500kV line in NSW1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: NSW1

Lines: Bayswater - Mt Piper No.5A3 500kV and Wollar - Mt Piper No.5A5 500kV

Cancellation time: 23/11/2020 19:09

Constraint set(s) revoked:
NONE

Refer AEMO Electricity Market Notice 80271

Auto-generated on behalf of Manager NEM Real Time Operations
     
80271RECLASSIFY CONTINGENCY23/11/2020 05:04:31 PM

Reclassification of a Non-Credible Contingency Event: Bayswater - Mt Piper No.5A3 500kV line and Wollar - Mt Piper No.5A5 500kV line in NSW1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.

Region: NSW1

Lines: Bayswater - Mt Piper No.5A3 500kV and Wollar - Mt Piper No.5A5 500kV

Duration: 23/11/2020 17:04 until further notice

Constraint set(s) invoked:
NONE

Auto-generated on behalf of Manager NEM Real Time Operations
     
80270RESERVE NOTICE23/11/2020 05:15:24 PM

STPASA - Forecast Lack Of Reserve Level 2 (LOR2) in the QLD Region on 30/11/2020 - AEMO Investigating.

AEMO ELECTRICITY MARKET NOTICE

STPASA published a Forecast LOR2 condition in QLD region for the following period:

From 1330 hrs to 2000 hrs 30/11/2020.
The forecast capacity reserve requirement is 406 MW.
The minimum capacity reserve available is 187 MW.

AEMO is currently investigating the cause of this forecast LOR 2 condition.

Manish Bhaskar
AEMO Operations
     
80269RESERVE NOTICE23/11/2020 04:05:39 PM

STPASA - Forecast Lack Of Reserve Level 1 (LOR1) in the QLD Region on 30/11/2020

AEMO ELECTRICITY MARKET NOTICE

AEMO declares a Forecast LOR1 condition under clause 4.8.4(b) of the National Electricity Rules for the QLD region for the following periods:

1. From 1430 hrs to 1600 hrs 30/11/2020.
The forecast capacity reserve requirement is 870 MW.
The minimum capacity reserve available is 756 MW.

2. From 1800 hrs to 1930 hrs 30/11/2020.
The forecast capacity reserve requirement is 700 MW.
The minimum capacity reserve available is 588 MW.

Manish Bhaskar
AEMO Operation
     
80268MARKET INTERVENTION23/11/2020 05:11:07 PM

Direction - SA Region - 23/11/2020

AEMO ELECTRICITY MARKET NOTICE.

Direction - SA Region - 23/11/2020

In accordance with section 116 of the National Electricity Law, AEMO has issued a direction to a participant in the SA region. For the purposes of the National Electricity Rules this is a direction under clause 4.8.9(a).

The direction was necessary to maintain the power system in a secure operating state.

AEMO may issue or revoke additional directions in order to meet the current requirement, unless sufficient market response is provided. A further market notice will be issued when all directions related to this requirement have been cancelled.

The issue of the direction commences an AEMO intervention event. AEMO declares all dispatch intervals during the event to be intervention dispatch intervals, commencing from the interval ending 1715 hrs on 23/11/2020.

Intervention pricing does not apply to this AEMO intervention event.

Manager NEM Real Time Operations
     
80266MARKET INTERVENTION23/11/2020 05:07:41 PM

Cancellation - AEMO Intervention Event - Intervention dispatch intervals - Direction SA region - 22/11/2020


AEMO ELECTRICITY MARKET NOTICE

Cancellation - AEMO Intervention Event - Intervention dispatch intervals - Direction SA region - 22/11/2020

Refer Market Notice 80237

The AEMO Intervention Event and all associated directions are cancelled from 1700 hrs 23/11/2020

Manager NEM Real Time Operations
     
80262MARKET INTERVENTION23/11/2020 03:21:09 PM

Possible intervention to manage power system security in South Australia (SA) Region

AEMO ELECTRICITY MARKET NOTICE

Possible intervention to manage power system security in South Australia (SA) Region

The synchronous generating units expected to be synchronised in SA from 0900 hrs 24/11/2020 to 1500 hrs 24/11/2020 in Pre-dispatch published at 1430 hrs 23/11/2020 are inadequate to maintain sufficient system strength in SA and hence a secure operating state.

AEMO currently estimates that, in the absence of sufficient market response by 1700 hrs 23/11/2020, AEMO may need to intervene by issuing a direction requiring one or more SA synchronous generating unit(s) to operate or remain synchronised to maintain power system security in SA.

Manager NEM Real Time Operations
     
80261RECLASSIFY CONTINGENCY23/11/2020 11:59:10 AM

Cancellation of a Non-Credible Contingency Event: Eildon PS - Mt Beauty No.1 220 kV line and Eildon PS - Mt Beauty No.2 220 kV line in VIC1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: VIC1

Lines: Eildon PS - Mt Beauty No.1 220 kV and Eildon PS - Mt Beauty No.2 220 kV

Cancellation time: 23/11/2020 11:59

Constraint set(s) revoked:
NONE

Refer AEMO Electricity Market Notice 80253

Auto-generated on behalf of Manager NEM Real Time Operations
     
80260NON-CONFORMANCE23/11/2020 11:40:12 AM

NON-CONFORMANCE Region QLD1 Monday, 23 November 2020

AEMO ELECTRICITY MARKET NOTICE

NON-CONFORMANCE QLD1 Region Monday, 23 November 2020

AEMO declared a schedule generating unit non-conforming

Unit: SWAN_E
Duration: 23/11/2020 11:30 to 23/11/2020 11:40
Amount: -12 MW
Constraint: NC-Q_SWAN_E

Auto-generated on behalf of Manager NEM Real Time Operations
     